Two tools, honest by design.

A pre-selector that names a candidate series and its limits — never a fake model promise — and a mesh↔micron converter that runs off the US sieve series, labelling exact, approximate and nearest-reference values separately. No email walls.

Tool 01

Machine pre-selector

Three questions. The result is a candidate series with its limits — sizing a specific model takes particle size, density, moisture and capacity data, ideally from a sample test.

  1. 1
  2. 2
  3. 3

What are you screening?

Tool 02

Mesh ↔ micron converter

Type either one — you get the other, the closest standard aperture, and whether the cut usually needs ultrasonic help. Both directions read the same reference table.

mesh

Exact match — US sieve series

Mesh (US std)
325
Aperture
44 μm
0.044 mm · 0.00173″
Anti-blinding
Ultrasonic advised
33 kHz keeps mesh clear

Exact match in the US sieve series — typical duty: metal powder guard.

Full mesh ↔ micron reference table
4 mesh4760 μmLump breaking guard
8 mesh2360 μmCoarse granule scalping
10 mesh2000 μmGranule scalping
12 mesh1700 μmGrain cleaning
16 mesh1180 μmFertilizer granules
20 mesh841 μmSugar guard cut
25 mesh707 μmPolishing grit
30 mesh595 μmSemolina cuts
35 mesh500 μmCourse flour
40 mesh420 μmSemolina / spice
45 mesh354 μmFine semolina
50 mesh297 μmGrain top-cut
60 mesh250 μmFlour top-cut
70 mesh210 μmTableting granules
80 mesh177 μmGeneral powder
100 mesh149 μmIcing sugar
120 mesh125 μmFine food powder
140 mesh105 μmCocoa / starch
170 mesh88 μmFine chemicals
200 mesh74 μmPigment cuts
230 mesh63 μmPharma powder
270 mesh53 μmFine pharma
325 mesh44 μmMetal powder guard
400 mesh37 μmFine pigments
500 mesh25 μmUltrasonic class

The approximation μm ≈ 15000 / mesh is accurate for mid-range; certify critical cuts against the sieve series.